MARMOT flux MTV125

Standard (SnPb) soldering » MARMOT fluxes for hand and wetting soldering » MARMOT flux MTV125

Technical Data Sheet

MTV125

 

Product name: 

 MARMOT® Flux MTV125

Description and key properties:

 

  • Organic flux for hand soldering with high reduction cleaning effect
  • Flux based on derivative of amino acid highly activated with content of halides
  • For hand soldering in electronics and general engineering
    with standard SnPb and lead-free solders
  • Useable everywhere  when water cleaning is applicable
  • Does not contain salt of heavy metals
  • High efficiency not only with color metals  but even with steel,
    nickel and noncorrosive steel  
  • Dilutable flux according to used process of soldering
    and solderability of soldered parts 
  • The flux is not suitable for soldering by naked flame – it is flammable

Operating manual:

Applicable by suitable tool before soldering

 

 

 

 

 

Technical specification:

Corresponds to norm:

Classification:

 

EN 29454-1     

2.1.2.C

Fully complies EU directive - RoHS

DIN

F-SW-25

 

J-STD

ORH1

Form

Solid

Aroma

Odorless

Density

1 + - 0,2

kg/dm3

Melting point

120

C

solidification point

90

C

Color

Colorless - light yellow

Spread factor – USA methodology MIL-F-14256D

86-92

%

Spread areal – EU methodology

220

mm2

Absolute corrosive  effect on  Cu mirror

Not applicable

- EN 29455-5 (ISO 9455-5:1992)

Not applicable

- USA method MIL-F-14256D:

Not applicable

corrosive  effect tropical humidity 21 days

Not applicable

Insulation resistance :

 

 

5kV distance 1mm

Not applicable

M ohm

PCB  distance 1 x 1mm

Not applicable

M ohm

electrical breakdown distance 1mm

Not applicable

KV

Soluble in:

Hot water

without limits

g/lit.

 

 

Recommended thinner :                

 

Recommended  cleaner:

Hot water, Isopropyl alcohol.

Used methodology conform  the norm MARMOT,  M01-3 for led free solders M01.1

Other proprieties: Solid substance read safety data sheet if released

For aviation and military devices is recommend cleaning, for other usage apply cleaning if there is risk of electrical leak. In all other application where the small residuum of the flux after soldering does not affect the product is not necessary to apply cleaning.

It is necessary to examine influence of the flux residue after soldering on soldered device.

 

Issued:

22.7.2008

Revised

25.01.2013

         

 

11.0.

Safety and health protection

 

 

11.1.

Long lasting and repeated contact with skin can cause irritation and sensibility, therefore is necessary to avoid direct contact.  In case when it is not possible exclude possibility of direct skin contact, the workers must wear suitable personal protective equipment. Work area must be ventilated. Do not drink or eat during work. Do not use naked flame. After work, hands should be washed with soap and warm water and cared with protective cream.

 

 

11.2.

First Aid

 

Inhalation – in case of excessive inhalation of flux fumes emitted during soldering, remove affected person to fresh air.

Ingestion – in case of accidental Ingestion, wash out mouth with water and give enough pure water to drink.

Skin contact – in case of skin contact, wash the place with soap and warm water.

Eye contact – in case of eye contact, flush the eyes immediately with plenty of water.

In case of large health damage or eyes contact, seek medical attention. 

 

11.3.

Above mentioned precautions are recommended for health protection of the workers, obligatory measures are described in Safety Data Sheet (SDS) - if released, and do not substitute internal safety regulations of final customer.